Boiler accessories, location, and function1- Boiler location : Boiler room Function : Generate steam or hot water in a c...
18/07/2022

Boiler accessories, location, and function

1- Boiler
location : Boiler room
Function : Generate steam or hot water in a closed vessel

2- Main steam stop
location : On the steam outlet of a boiler
Function : Place the boiler on line or off line.

3- Guard valve
location : On the steam outlet of a boiler directly following the main steam stop valve
Function : Guard or backup to main steam stop

4- Daylight (drain) valve
location : Between the main steam-stop valve and the guard valve
Function : Open only when the main steam and guard valves are closed. Indicates if one of the valves is leaking through.

5- Main steam line
location : The line that conveys steam from a boiler to all branch or distribution lines. When a system is supplied by a bank of boilers connected into the same header, the line(s) conveying steam for the boiler(s) to the header
Function : Carry steam from the boiler to the branches or distribution lines.

6- Root valve
location : Installed in branch or distribution lines just off of the main steam line Function
Function : Isolate a branch or distribution line (serves as an emergency shutoff).

7- Pressure regulating valves (PRV)
location : Installed as close as practical (after a reducing station) to the equipment or area it serves
Function : Equipment that requires lower pressure than main steam line pressure (coppers, dishwashers, steam chests, or turbines)

8- Steam trap
location : installed on the discharge side of all steam heating or cooling equipment, dead ends, low points, or at regular intervals throughout a steam system (automatic drip legs)
Function : Automatically drains condensate and prevents the passage of steam through equipment

9- Drip legs
location : Provided throughout a system where condensation is most likely to occur, such as low spots, bottom of risers, and
Function : Remove condensate from a system manually.

10- Temperature regulating valve (TRV)
location : Install in the steam supply line close to equipment needi

Cochran Boiler and parts. .
18/07/2022

Cochran Boiler and parts. .

Address

Shravan
Bharuch
392001

Opening Hours

Monday 9am - 5pm
Tuesday 9am - 5pm
Wednesday 9am - 5pm
Thursday 9am - 5pm
Friday 9am - 5pm
Saturday 9am - 5pm

Telephone

+919978331081

Alerts

Be the first to know and let us send you an email when Safequip services posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Safequip services:

Share